glue intake control (Gelierprobe)

water quench
|
| water quench useable space: |
deep-drawn, laser welded stainless steel-vat, length x width x height: 468 x 356 x 238 mm |
| housing: |
structure stainless steel material 1.4301, stainless steel flat top cover, digital microprocessor-PID-regulation up to 95,0°C using "no contact" switch, tenth degree precise digital reference input and display of current data (LED), fully integrated self-test-system, malfunktion-display, over-temperature safety device, device is safety tested |
| dimensions: |
length x width x height: 468 x 356 x 238 mm |
| netto weight: |
ca. 11 kg |
mobile measurement-capture- and evaluation system for temperature- and humidity measurement
Opus 1
Smartgraph
| application: |
climate regulation monitoring, proof of production and storage conditions. Electronic thermo-hygrograph for fully automatic, high-precision registration of temperature and humidity. |
| description: |
The up to date alternative to the thermo-hygrograph ! digital temperature and humidity display (illuminated), zoom-function, graphic timeline, dayly, weekly, monthly, and annual data protocol, data logging, longtime data storage and alarm function, external sensors (optional), data interface for other software, SmartGraph-software (WindowsTM compatible), table or wall mountable, battery or AC-adaptor powered (220V/110V), optional burglarproof wallmount avaliable.
|
Opus 10 THI and TSE
Shapely, manipulation resistent datalogger (storage for 120 000 measurements) you can oerder Opus 10 with integrated T/rF - sensor or with interface for one or two external rF/T- sensors (same price, excl. sensor) very convenient: the display showes, if logging is aktive - standard software is included - with additional SmartGraph software you are able to export your logs to exel - you can mount the device direct on the wall.
| precision: |
±3% rF, 0,3°C at 0 - 40°C, ± 2% rF with external sensor |
| resolution: |
0,5% rF; 0,1°C |
| long ternm stability: |
drift < 0,5 - 1% rF / year |
| calibration possibility: |
interner Sensor nicht kalibrierbar, externer Sensor ja |
| effective range: |
0 - 95% rF (no dew), ext. Sensor: 0 ...100% rF |
| temperature range: |
-20° bis +50°C, externe Sensoren siehe unten |
| measurement interval: |
1/10/30 sec, 1/10/30 min, 1/3/6/12/24h |
| logging interval: |
1/10/30 min, 1/3/6/12/24h |
| interface: |
RS 232 |
| battery: |
3,6 V lithium, replacable, lifespan 2 years, battery charging level indication at start-up |
| dimensions: |
115 x 110 x 25 mm, weight: 250 g
|
multitalent in measurement technology equipped with digital sensor interface and PT100 input for temperature measurement
A1-SDI
instead of many measuring instruments for individual tasks - with the A1-SDI you just need one device for various measuring scenarios ! excellent clearness of display, illuminated screen, hold, max, min, average value, automatic switch off, one point calibration, PT100 input, thumb wheel, realtime clock, °C/°F switchable.
| power supply: |
4 x 1,5V (AA), alkali-mangan |
|
| standing time: |
190h (without sensors) |
|
| log rate: |
0,5 s |
|
| technology: |
PT100 (3-conductor) |
|
| work temperature: |
-200 .. 500 °C |
|
| precision: |
±0,5°C (without sensor) |
|
| resolution: |
0.1 °C |
|
|
 storage: |
 operation: |
| ambient temperature limit: |
-20...60°C |
0...50°C |
| max relative humidity: |
< 90% rel. humidity or < 20g/m³ (smallest value is imperative) |
< 95% rel. humidity non-condensing |
| max. altitute: |
5000m above sealevel |
5000m above sealevel |
thermo-hygrometer with fixed sensor
E200
facility climate monitoring in switch cabinets and store rooms, dewpoint and absolute humidity, hold, max, min, average value one point calibration, operation in °C/°F
| power supply: |
9V block battery |
|
| standing time: |
typ.>150h |
|
| store temperature: |
-30...60°C |
|
| dimensions: |
175x48x25mm |
|
| work temperature: |
0...50°C |
|
| weight: |
ca. 200g |
|
| functions: |
HOLD / MAX / MIN / AVG / Unit1 / Unit2 / CAL1 / CAL2 |
|
 temperatur: |
 rel. humidity: |
| technology: |
NTC |
capacitive |
| measurement range: |
-20 .. 50 °C |
5 .. 95 % r.F. |
| precision: |
±0,4°C (0...40°C), beyond ± 0,7°C, + 1 Digit |
±3% r.F., + 1 Digit |
| resolution: |
0.1 |
0.1 |
mechanical drumrecorder
drumrecorder
A thermo-hygrograph is used for measurement and logging of air temperature and relative air humidity (RH). The logging function is done by a clockwork driven drumrecorder. These robust and reliable precise products have prooven during decades of operation in the fields of science, economy, culture and weather stations all around the globe. They are suitable for personal or commercial use.
Darroven UNB100
Darrbalance
|
The Darroven und balance are made for the Darrprobe according to DIN 52183
| stove: |
Solide construction. Steel housing, powder-coated, stainless steel interior. Heating is done by heating element wich will be placed below the chamber floor. The monitoring system consists of an hydraulic safety thermostat with calibrated scaleadjustment. Overheating protection, temperature display. The entire housing is made for continuous operation, safe and thermoisolated. |
| electronic compactbalance: |
precise, handy - fast adjustment of precision - calibratorweight included - stainless-steel balanceweight - easy 4-button operation - power supply by battery or AC adaptor 230 V.
|
GTH 400 fast-digital-pocket-thermometer
GTH 400
features:
- suitable to use as glued joint thermometer
- battery operation
- measurement range –50…+1150°C
- resolution 1°C
- sensor interface 2-pin norm-flatplug (thermostrainless)
compatible for all NiCr-Ni-sensors
- 3 1/2-digit, 13 mm high LC-Display
- work temperature 0 - 45°C
- power supply 9V-battery type IEC 6F22 (included in delivery)
- battery lifespan ca. 700 hours of usage, battery change indicator in display
- accessory: thermo wire sensor for glued joints and/or surface sensors
device for RPM and speed determination as well as for measurement of length
- The handy device operates in two diffrent modes: optical (without contact) and mechanical (using an adaptor and diffrent measurement attachments)
use to monitore the laminating pressure
load cell
| working range: |
0 – 100 kN, scale 2 kN with analogue index, manometer NG 100, measurement chain complete adjusted, measurement precision +- 1% v. SE |
| optional: |
with two connection plugs, length 100 mm or with flexible CU-connection 2 m length
|
JAS cuvette-test formaldehyde
equipment for internal monitoring of gluelam formaldehyde emissions according to MAFF
- acryl-closet plus cover with circular seal
- volume ca. 38 litre
- acrylbasin with cover for distilled water
- download description cuvette-test (PDF, 28kb)
Lasa 30 - laboratory photometer for routine-analylis determination of formaldehyde concentration in gluelam according to MAFF for internal quality assurance
- LangeNET® and data mobile*
- battery operation possible
- reference beam technology
- auto-zero-adjustment, cuvette-test, pipette-test
- possibility to develope own methods
- measurement store for 100 values
- use of special filters possible
- extinction measurement, transmission measurement, measurement of concentration with a factor
- input of linear von linearen calibration curve
- display of time and date
- RS-232-interface
- download: short manual (PDF, 808 kb)
infrared thermometer
| features: |
data hold for short time data storage °C/°F-switchable laser which can be switched off adjustable alarm setup min-/max-/avg measurement backround illuminated additional contact-temperature measurement with optional K-type-sensor |
| measurement range: |
–50 bis +750°C (resolution 0,1°C - precision +/- 2°C or 2%) |
| optic: |
13:1 |
| response time: |
< 1 s |
| emission ratio: |
adjustable 0,1 to 1,0 |
| power supply: |
9V block battery |
| dimensions: |
180 x 106 x 48 mm (gun shape) |
| weight: |
ca. 250 g |
| included in delivery: |
device with bag, battery and manual |
hydromette M 2500 microprocessor controlled timber moisture und temperature indicator - data storage - interface to connect with a PC or printer - big 4 line matrix-display - work range 4 bis 100% wood moisture or –30 to +170°C - special calibration for licensed gluelam construction (DIN 1052) - approved by the Otto Graf institute in stuttgart - precise moisture measurement in trimmed timber (up to 180 mm in diameter) in veneers and measurement of air and material temperature, single or group measurement and data storage - guided operation and malfunction message important features and technical data:
- length: 190mm x width: 115mm x height: 56mm - weight: 460g without accesories
- data storage of 3000 timber moisture values and 3000 temperature values including date and time
- characteristic curves of 250 timber kinds are stored in fixed memory
- direct connection to a PC or printer to transmit the data
- automatic temperature compensation of the timber-moisture-measurement values utilizing a connected timber temperature sensor or by manually entering the values
- statistic interprtation of the measurements by min, max, avg values
- power supply: 9-V-block battery or Ni-Cd-akkumulator or 12-V AC-adaptor (optional).
(device ships without accesories)
measurement range: timber moisture: 4–100% depending on the resistor-measurement-method temperature 1: –30 to +170°C depending on the used sensor |
accesories: timber moisture measurement electrodes (6) temperature measurement electrodes (10) flexible Pt-100 temperature sensors (5) |
GTH 400
fast-digital-handthermometer features:
- usable as glued joint thermometer
- battery operation
- maesurement range –50…+1150°C
- resolution 1°C
- sensor interface 2-pin norm flat-plug (thermostrainless)
compatible with all NiCr-Ni-sensors
- 3 1/2-digit, 13 high LC-Display
- workrange 0 bis 45°C
- power supply 9V-battery type IEC 6F22 (included in delivery)
- battery lifespan ca. 700 hours of operation, battery change indication
- accesories: thermo wire sensor for glued joints and/or surface sensors
GTH 1150
fast-digital-thermometer
| measurement range: |
-50 °C to 1150 °C |
| resolution: |
1 °C |
| precision: |
better 1% ± 1 digit (-20...+550°C) |
| sensor interface: |
all NiCr-Ni (typ K) temperatur sensors with 2-pin norm flat-plug attachable - temperatur sensor not included |
| please note: |
we have listed some standard sensors at our various products page |
|
|
| download: |
productsheet (PDF, 36 kb) accesories (PDF, 150kb) sensorlist 1 (PDF, 252kb) sensorlist 2 (PDF, 260kb) |
hand marking punch for timber identification innovative hand marking punch with tenon - suitable for use in a moulding press - punches 3 - 10 digits in gluelam, timberconstructions, balks etc. Each whell has 11-sides with numbers / letters and a blank engraved. The last wheel can be engraved as block wheel according to customer requirements. All the wheels can be rotated back and forth manually - automatic locking device for a cleaner typeface - a removable cap protects the blow ergonomic handle shock.
- New classification according to DIN 1052-1, para 14
- The font height is selectable between 8 and 10 mm.
- Download product sheet (PDF, 32kb)
rotary type holder rotary type holder for the labeling of Glulam on a planing machine (according to DIN 68140-1, para 8) intended to host the exchangeable segment types for endless marking, suitable for fitting to thicknessers - consisting of the typeholderwheel, as well as the type clamp segment - changing the segement types is easy and goes very quickly - rollerbody made of burnished steel - special designs on request tt is possible mount single and block segment types of partial and complete assembly according to customer requirements
specifications:
- burnished steel roller body
- roller body dimensions: max. 300 mm, width, depending on the font height, with a bore according to your shaft, with keyway
- segment types (see above, steel types) made of alloy tool steel, rapidly changeable
- font height: 2 - 10 mm, to 1,5 mm sublime graved
- gravure: individual types 0-9, A-Z or blocks, as well as blank types and signs according to customer requirements
documentation of the production data for glued parts according to DIN 1052 proof A, B and D
|